PlaneSystem® by MDT Udo Plaster developed in cooperation with Zirkonzahn 




An innovative approach for capturing and measuring patient-specific occlusal information:
 
  • position of the upper jaw,
  • inclination of the occlusal plane,
  • bite position,
  • occlusal surface design,
  • tooth set-up,
  • lower jaw’s function analysis,
  • and its relation to the upper jaw.

For a precise planning security, a comprehensive patient consultation and better communication between patient, dentist, orthodontist and dental technician.

Advantages
 
  • inaccurate results through facebows or transferbows can be avoided,
  • all data can be accurately matched in the articulator by means of reproducible reference planes,
  • integration of data for functional analysis carried out by dental professionals,
  • articulator with an innovative design,
  • completely integrated in the digital workflow.

Reference planes – what’s new?

When detecting the patient’s reproducible Natural Head Position (NHP) by means of the PlaneFinder®  measuring/registering device, it is usually possible to localise a horizontal reference plane for the patient‘s skull in the repeatable manner. During the registration, the patient intuitively positions the midline vertically and in the center of the device which allows the user to visualise and record the asymmetries from the patient‘s face on the right and left side of this vertical reference plane.


For information about PlaneSystem® courses please contact:
info@plasterdental.de  |  www.plasterdental.de
 

“Already with the transmission of the patient’s situation with the PlaneSystem®, the dental technician can save a lot of time, since the planes fit immediately. There is no longer the need to subsequently correct them which is mostly the reason for unnecessary time wastage and modifications. Just a little practice is necessary for its application. If everything is coordinated well, the transmission and bite registration takes more or less the same amount of time as with conventional working methods. […] This development is still very new to many customers. A dental technician can provide information and consult dentists, for example by means of brochures. In order to support this workflow and to get “best” data from it as a result, I often brought the PlaneFinder® along when I visited my customers. A small laboratory makes this unconventional approach possible. With my own initiative I was able to convince my customers to collaborate with me, since the detection of the patient’s situation is usually the dentist’s task.  […] Basically, the amount of work for a dentist is not much, less than when applying conventional working methods.” Dental technician Karin Engelhart (Dental-art laboratory, Tönisvorst). Interview with the Quintessence Zahntech magazine, 2016;42(4):531-535.




Planesystem®-Components
 
PlaneFinder®
Device used to detect the Natural Head Position (NHP) as well as the occlusal plane angle

товарный номер: SYAA0360
PS1 Articulator
Physical and virtual articulator designed with special geometries to simulate patient-specific rotating, sliding and closing movements of the jaw as they occur during mastication

товарный номер: SYAA0350
PlanePositioner®
Platform used to position the maxillary cast in the PS1 articulator and to reproduce the occlusal plane

товарный номер: SYAA0370


Ideal in combination with
 
Face Hunter
Scanner for the photo-realistic 3D digitisation of faces as a working basis for the manufacture of individualised dental prostheses

 
товарный номер: SYAA0310
PlaneAnalyser II
Instrument of analysis for recording and documenting the patient’s specific movements of the mandible (as well as for adjusting the articulator)


Planesystem®-ACCESSORIES
 
Set Adjusting Key PS1
Set consisting of: 1 x Zero Adjusting Pin PS1 and 1 x Adjusting Key PS1
Set of fixing keys for the PS1 articulator. For bonding different split-cast systems and achieving synchronisation between several PS1 articulators.

 
товарный номер: ZBAC1971
JawPositioner (46 pieces)
With the PlanePositoner®, it allows to transfer into the laboratory’s articulator the digitally articulated models (maxilla)

 
товарный номер: ZBAC3501
JawPositioner Support
Support for fixing the JawPositioner in the orbit of the Zirkonzahn milling unit

товарный номер: ZBAC3511
Set of inserts for the PS1 articulator
Inserts for adjusting the surtrusion and the detrusion of the articulator

товарный номер: ZBAC1901
Reference Transfer Plate
For the determination of the reference plane within the PlanePositioner®, in order to reference the maxilla in the Plane Analyser

товарный номер: ZBAC1921
Multi Marker Plate
Positioning attachment for Easy Fix model holder for scanning the Transfer Fork Face Hunter in the Zirkonzahn scanner

товарный номер: ZBAC1931
Bite Tray PlaneFinder® 1-3
Support made from sterilisable resin for the registration of the occlusion in the PlaneSystem®

товарный номер: ZBAC2154
Bite Tray PlaneFinder® 2-4
Support made from sterilisable resin for the registration of the occlusion in the PlaneSystem® (larger size)

товарный номер: ZBAC2156
Spacers for Bite Tray PlaneFinder®
Accessories used in cases of edentulism. In combination with the Bite Tray 1-3 and 2-4 they allow to register the height properly.

товарный номер: ZBAC2158
Plaster Plates 5 mm
Plates used to set up the teeth on the PlanePositioner® (3 pieces)

товарный номер: ZBAC2351
Plaster Plates 5 mm splited
Splited plates used to set up the teeth on the PlanePositioner® (6 pieces)

товарный номер: ZBAC2361


An overview of the workflow

Registration of data (in the dental practice)
 
Position of the maxilla in the Natural Head Position (NHP):
 
Manually
With registration material on a (horizontally aligned) tray on the PlaneFinder®.

Digitally
With the Face Hunter and the PlaneFinder®.
Inclination of the ala-tragus reference in the Natural Head Position (NHP):
 
Manually
On both sides with measuring angles on the PlaneFinder® in relation to the horizontal reference plane.

Digitally
Indication of the relevant anatomical points (Ala nasal/Ala Tragus) on the 3D Face Hunter scan, automatic measuring through the software.
Mandibular movements:
 
Digitally
With the jaw registration system Plane Analyser (does NOT replace an expert functional analysis carried out by dental technical qualified personnel).


Data transfer into the PS1 articulator (in the dental practice or in the lab)

The captured data are then matched in the PS1 articulator on the basis of the horizontal reference plane.
 
Position of the maxilla:
 
Manually
Alignment of the registration material on the (horizontally positioned) PlanePositioner® on the basis of further parameters (skelatal midline/masticatory centre), insertion of the PlanePositioner® in the PS1 articulator, inserting the maxillary model in the registration material and plastering the model on the upper articulator arm.

Digitally
Through matching, the model is brought into the correct position in the facial scan with the help of the Transfer Fork (Bite Tray Face Hunter)

Digital data concerning the position of the maxilla can be transferred at any time into the laboratory articulator to carry out manual control steps or working steps. To do so, an occlusal positioning pattern is milled out of the JawPositioner milling blank with one of the Zirkonzahn milling units, and is then placed on the PlanePositioner®, similar to the registration material in the conventional data registration.
 
 
 
Inclination of the ala tragus line/occlusal plane:
 
Manually
Display of the occlusal plane (which can have a varying inclination) by adjusting the measured “ala tragus angle” with the help of the two pivoting halves of the table on the PlanePositioner®.

 

Digitally
Has already been carried out during data registration
Mandibular movements:
 
Manually
Settings for the PS1 articulator result from the Plane Analyser’s measurement log.

Digitally
Import function in the Zirkonzahn.Modellier software (in preparation).
 
The digitisation of the manually captured data is carried out with the S600 ARTI model scanner and the Zirkonzahn.Scan software. Subsequently, they can be combined with patient photos or 3D facial scans (Face Hunter). The entire system can be ideally combined with the model-/patient analyses according to Udo Plaster.


The third dimension in patient analysis
In clinical practice, incorrectly inclined occlusal planes and functionally inadequate restorations are a common scourge. A possible reason is the often imprecise analysis of patient information. Now Udo Plaster, master dental technician from Nürnberg, has developed a novel transfer approach, the PlaneSystem®.
It determines the occlusal plane and any associated asymmetries individually for each patient based on the ala-tragus plane and natural head position (NHP) and transmits the real position to the CAD/CAM system.
For an uninterrupted digital workflow, the data received and the corresponding coordinates in three-dimensional space must be correctly matched. This can be done with the S600 ARTI structured-light optical scanner and the virtual articulator implemented in the Zirkonzahn design software. The scanner acquires the data of the models from the PS1 articulator and transfers them directly to the software’s virtual articulator.
This allows possible compensations to be detected prior to developing a treatment plan for laboratory or chairside restorations, minimising or completely eliminating any sources of error, particularly during data transfer, which might otherwise occur when planning or fabricating a dental restoration.



The next step is the actual modelling of the restoration in the design software Zirkonzahn.Modellier. Ideally, the physiognomy of the patient is taken into account during this step. This is now made possible by the Face Hunter 3D facial scanner.
The almost photo-realistic digital face data of the patient can be used either as validity or reference values, but are also ideal for the planning and consultation process between dentist and patient.


Scientific background to the Plaster transfer approach
Ala-Tragus Line



Scientific studies, e.g. by Xie and coworkers, have identified the connecting line from the lower edge of the nasal wing to the centre of the tragus, the so-called ala-tragus line, to be a more reliable reference for the occlusion line than Camper’s plane or the Frankfurt horizontal plane. The deviation of the ala-tragus plane from the occlusal line is minimal. The ala-tragus line varies from patient to patient, with hemifacial asymmetries a not infrequent occurrence. In order to reliably reproduce the occlusal plane, it is necessary to determine it independently of skeletal class.


The Natural Head Position (NHP)



The second important point of reference within Plaster’s method of transfer is the natural head posture (NHP). A 5-year study by Cooke (2) has shown that patients’ natural head posture varies by only one to two degrees when looking directly into his or her own eyes as they stand upright in front of a mirror. This result is supported by a 15-year study by Peng et al.
The NHP is related to a patient-independent reference frame that allows patient-specific variations in spatial orientation to be reproduced.




 

Download


Brochure Components for patient digitisation



 


Topic-related Studies and Specialist articles
  • Plaster U. Natürliche Asymmetrien und die patientenindividuelle Wiedergabe der Okklusionsebene ohne traditionellen Transferbogen.
    Quintessenz Zahntech 2013;39(5): 1266-1280
  • Xie J, Zhao Y, Chao Y, Luo W. A cephalometric study on determining the orientation of occlusal plane.
    Hua Xi Yi Ke Da Xue Xue Bao. 1993 Dec;24(4): 422-5
  • Sinobad D, Postic SD. Roentgencraniometric indicators of the position of the occlusal plane in natural and artificial dentitions.
    Eur J Prosthodont Restor Dent. 1996 Dec;4(4): 169-74
  • Cooke MS. Five-year reproducibility of natural head posture:A longitudinal study.
    Am J Orthod Dentofacial Orthop 1990; 97: 487-94
  • Peng, L. Cooke, MS.: Fifteen-year reproducibility of natural head posture: A longitudinal study.
    Am J Orthod Dentofacial Orthop 116 (1) 1999: 82-85